weiter

MIKA-SCOMP

Enclosed medium voltage systems are frequently preferred solutions where the safety of the equipment and of people is important.

To provide a higher level of safety for operators when a fault (short-circuit/arc inside the system) occurs, this system type has strong double walls, door locks, pressure relief flaps with monitoring, a sophisticated ventilation concept, arcing fault deviation plates, partitions between the different units and a number of other features.

Like with the ECOMP system, the SCOMP also is available in three versions: -F / -E / -A. Each of these versions can be implemented both as pure power factor correction and as filter application.

Be safe, take "Scomp"!

FEATURES

  • Tested for resistance to accidental arcing 25 kA/15 acc. to IEC 60298 1990 IAC test
  • Max. grid voltage 12 kV
  • up to 6 compensation steps (totally max. 12 Mvar)
  • Protection IP41D
  • 2 mm thick double walls and doors
  • Indicator light - Fault
  • Temperature, unbalance, door and pressure relief flap monitoring
  • Large variety of expansion and enhancement options
  • Integrated grid analyzer with several communication interfaces
  • Door lock

Technical Specifications

Operating voltage 1 kV - 12 kV*
Control voltage 230 VAC / 220 VDC* (fused)
Nominal frequency 50 / 60 Hz
Insulation level20 / 60 kV
 28 / 75 kV
Nominal power 50 kvar - 2500 kvar* each step
Capacitor typesC-Serie (C03)
(capacitors with 2 power sections + unbalance monitoring)
E-/G-Serie (E03, E06, G06)
 (single-phase capacitor + unbalance monitoring)
Design versions-F (fixed step)
 -E (with contactor for external actuation)
 -A (system wizch automatic actuation)
Tuned frequency189 Hz (7 %)*
 LINR inrush current limiting reactor
Protection IP41D
Ambient temperature 0 °C to 35 °C*
Installation site Indoor
Altitude < 1000 m above sea level
Impregnating material Faradol / Jarylec
Norm IEC 60871-1 / IEC 60071 / IEC 60282-1 / VDE 101
Commodity code 85.37.20.91
Finish RAL 7035
Dimensions (W x D x H)Capacitor unit: 1000 x 1200 x 2054 mm
 Incoming feeder/reactor unit: 800 x 1200 x 2054 mm
OptionalDischarge voltage transformer, heating, ventilation, voltage transformer, definite-time overcurrent-time protection, incoming feeder with optional breaker / grounding switch, touch panel, link-up with process control system, etc

If you have questions about our MIKA product family, please contact Mr. Manuel Schörmann:

[Translate to Englisch:] Ansprechpartner öffnen

Manuel Schörmann
Condensator Dominit GmbH
An der Bremecke 8
59929 Brilon
Tel: 02961 782 58
E-Mail: manuel.schoermann(at)dominit.eu